Double output solar temperature compensating controller SR-2L
Double output solar temperature compensating controller SR-2L
Double output solar temperature compensating controller1.PWM2.12V/24V3.Individual control4.double MOS series circuit
Double output Solar charge controller SR-2L
1. Individual control.
2. Five kinds of load working mode.
3. Adopts double MOS series circuit.
4. PWM charging mode.
5. Double digital LED display.
6. Use industry-specific chip and precision components.
Model | SR-L series | |
rated charging current | 5A ,10A ,15A ,20A (Optional) | |
Rated discharging current | 5A ,10A ,15A ,20A (Optional) | |
Working Voltage | 12V ; 24V ; 12V/24V Auto | |
No load losses | <5mA; | |
Charging circuit voltage drop | Less than or equal to 0.20V | |
Discharge circuit voltage drop | Less than or equal to 0.15V | |
Over voltage protection | 17V;×2/24V; | |
boost charge voltage | 14.6V; ×2/24V (duration time: 30 minutes) used every 7 days or when the battery is over discharged | |
Direct charge voltage | 14.4V;×2/24V (duration time: 30 minutes) | |
Float charge voltage | 13.6V;×2/24V | |
Charge recover voltage | 13.2V;×2/24V | |
Over discharge recover voltage | 12.5V;×2/24V | |
Lower voltage indication | 12.0V;×2/24V | |
Over discharge voltage | 11.1V;×2/24V | |
Temperature compensation | -4.0mV/°C/2V(boost voltage, direct charge, float charge and charge return voltage compensation) | |
Control method | PWM Smart Charging | |
Working temperature | From -35°C to +65°C; | |
Over-load and short circuit protection | 1.25 rated :loads current 30sec, 1.5 rated: loads current 5sec, over load protection action. ≥3 Rated: load current short circuit protection action. | |
Circuit protection | Over-charge, over-discharge, short circuit and over-load protection | All the protections are harmless to any parts and fuse of controller |
Anti- connection-reverse protection for solar battery and storage battery. |
Solar street light system solution